CVE-2024-49775

NameCVE-2024-49775
DescriptionA vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
SourceCVE (at NVD; CERT, ENISA, LWN, oss-sec, fulldisc, Debian ELTS, Red Hat, Ubuntu, Gentoo, SUSE bugzilla/CVE, GitHub advisories/code/issues, web search, more)

Notes

NOT-FOR-US: Siemens

Search for package or bug name: Reporting problems